Description Command Root Command
Usages
Command Syntax Range,
Units
Command
Example
Response Example
Ch 3
A3L Query ? A3L 0 to 1000 %RP ? A3L -10.00
High Alarm,
Ch 3
A3H A3H Set = A3H ARG1 0 to 1000 %RP = A3H 110 OK
A3H Query ? A3H 0 to 1000 %RP ? A3H 110.00
Ch 3 Alarm
Enabled
While Off
IGNORE_CH3_AL
M
IGNORE_CH3_
ALM Set
= IGNORE_CH3_ALM
ARG3
ARG1:
0 - Outputs Off
1 - Outputs On
= IGNORE_CH3_ALM 1
OK
IGNORE_CH3_
ALM Query
? IGNORE_CH3_ALM
ARG3
0 - Outputs Off
1 - Outputs On
? IGNORE_CH3_ALM
1
Ch 3 Gain
GAIN3 GAIN3 Set = GAIN3 ARG1
50 - 150 % = GAIN3 60 OK
GAIN3 Query ? GAIN3
50 - 150 % ? GAIN3 60.00
Ch 3
Deviation
High Alarm
A3DH A3DH Set = A3DH ARG1
ARG1:
0 - 500 units
= A3DH 20 OK
A3DH Query ? A3DH 0 - 500 units
? A3DH 20.0
Ch 3
Deviation
Low Alarm
A3DL A3DL Set = A3DL ARG1
ARG1:
0 - 500 units
= A3DL 10 OK
A3DL Query ? A3DL 0 - 500 units
? A3DL 10.0
Ch 3
Deviation
Alarms
Enabled A3DE A3DE Set = A3DE ARG1
ARG1:
0 - Disabled
1 - Enabled
= A3DE 1 OK
A3DE Query ? A3DE
0 - Disabled
1 - Enabled
? A3DE 1
Ch 3
Deviation
Alarm Delay
A3DT A3DT Set = A3DT ARG1
ARG1:
0 - 7300 Seconds
= A3DT 3600 OK
A1DT Query ? A3DT 0 - 7300 Seconds
? A3DT 3600
High Res
Analog Gain
HIGH#_GAIN
HIGH#_GAIN
Set
= HIGH#_GAIN ARG1
# - A High Res Input 1 - 6
ARG1:
25-200% Gain
= HIGH#_GAIN 105 OK
HIGH#_GAIN
Query
? HIGH#_GAIN # - A High Res Input 1 - 6
? HIGH#_GAIN 105
High Res
Analog Offset
HIGH#_OFF HIGH#_OFF Set = HIGH#_OFF ARG1
# - A High Res Input 1 - 6
ARG1:
-100 to 100 units
= HIGH#_OFF 5 OK
HIGH#_OFF
Query
? HIGH#_OFF # - A High Res Input 1 - 6
? HIGH#_OFF 5
Vista de pagina 301